Abstract
To reduce the losses of power inverters, resonant topologies replace hard switching power inverters. This paper shows the first investigations and measurements carried out to design a three phase current link power inverter in ARCP (Auxiliary Resonant Commutated Pole) topology as well as the finally measurements and results achieved with the complete system.
Zitieren
1.
Canders W-R, Lescow N, Hinrichsen F. Three phase current source auxiliary resonant commutated pole inverter using IGBTs. In: 2007 European Conference on Power Electronics and Applications. Aalborg, Denmark ; 2007:1-11. doi:10.1109/EPE.2007.4417218.
Canders, W.-R., Lescow, N., & Hinrichsen, F. (2007). Three phase current source auxiliary resonant commutated pole inverter using IGBTs. In 2007 European Conference on Power Electronics and Applications (S. 1–11). Aalborg, Denmark . http://doi.org/10.1109/EPE.2007.4417218
Canders, W.-R., N. Lescow, und Frank Hinrichsen. 2007. „Three phase current source auxiliary resonant commutated pole inverter using IGBTs“. In 2007 European Conference on Power Electronics and Applications, 1-11. Aalborg, Denmark . doi:10.1109/EPE.2007.4417218.
Canders, W.-R., N. Lescow, und Frank Hinrichsen. „Three phase current source auxiliary resonant commutated pole inverter using IGBTs“. 2007 European Conference on Power Electronics and Applications. Aalborg, Denmark : N.p., 2007. 1–11.
Canders, W.-R., u. a. „Three phase current source auxiliary resonant commutated pole inverter using IGBTs“. 2007 European Conference on Power Electronics and Applications, 2007, S. 1–11.
Details
-
Number of Pages
1-11 -
Conference Location
Aalborg, Denmark -
ISBN Number
978-92-75815-10-8